# Research paper: Experimental Demonstration of High-Power Thermal Test Vehicle using Two-Phase Cooling for AI Datacenters, 5G RAN, and Edge Compute Nodes — retained record

> Retained semantic-scholar record from semantic-scholar.

Canonical: https://highsignal.app/data/records/053e01b5ab68def7

[← sources](https://highsignal.app/data)


source: [semantic-scholar](https://highsignal.app/data/semantic-scholar) published 2025-05-27 00:00 ingested 2026-07-21 08:13

[original source ↗](https://www.semanticscholar.org/paper/23063ac44eb6dbf65dd70fc0aea3a457788361f0)

## retained text



```
Query: ai datacenter power cooling efficiency
Authors: Yang Liu, Rishav Roy, David J. Apigo, Manohar Bongarala, Syed Faisal
Citations: 1
The increasing thermal demands of high-performance computing in AI datacenters, 5G radio access networks (RAN), and edge compute nodes necessitate the use of advanced cooling solutions beyond conventional air cooling. Multi-chip modules (MCMs), integrating CPUs, GPUs, and high-bandwidth memory (HBM) in 2.5D and 3D architectures, are now drawing power more than 1000 W. Assessing the efficiency of cooling solutions capable of dissipating such high heat loads requires developing a high-power thermal test vehicle (TTV) capable of mimicking the heat maps of the state-of-the-art and next generation CPUs and GPUs. This study demonstrates the high heat dissipation capacity of TTV while cooling it with a two-phase microchannel heatsink. At the core of the developed TTV is a multi-chip module consisting of six emulated logic dies (20 mm x 20 mm) and twelve emulated HBM stacks (10 mm x 10 mm) on a low-temperature cofired ceramic (LTCC) interposer, capable of dissipating more than 2600 W with localized hotspots reaching 314 W/cm2 (817 W/cm2 over the heater resistor area). The module consists of 264 platinum resistive temperature detectors (RTDs) for high-resolution thermal monitoring and enables independent power control across 60 heater regions, facilitating diverse spatial heat maps. The TTV was integrated into a pumped refrigerant cooling system utilizing the low-global-warming-potential (GWP) refrigerant R1233zd(E) in a heat sink with embedded microchannels. Two-phase cooling successfully handled heat fluxes up to 314 W/cm2over a 46 mm2hotspot on each logic die while maintaining thermal resistances below 0.013 K/W, demonstrating its ability to prevent dryout and thermal runaway at extreme power densities. The experiments also highlighted the superior thermal performance of two-phase cooling over single-phase approaches, achieving up to a 2.8x reduction in mean junction-to-heatsink inlet saturation thermal resistance and reducing peak chip temperatures by up to 25°C. This study demonstrates the utility of the TTV for emulating next-generation high-power computing platforms and the use of two-phase cooling as an advanced thermal management solution for future AI, 5G, and edge computing infrastructures.
```



document fetched 2026-07-23 08:17 · canonical https://semanticscholar.org/paper/23063ac44eb6dbf65dd70fc0aea3a457788361f0
